5-22 Configuration and Programming

Module Status Inputs

While the Module is operating in the command mode, its status is
reported to the SLC Processor via the command mode input image
table. This input file has the following format.

Input Word 0

bit 0

is set when the axis is moving CW

bit 1

is set when the axis is moving CCW

bit 2

is set when Module is in hold state

bit 3

is set when axis is stopped (typically used with an
immediate stop or a pulse train disable)

bit 4

is set when axis is in home position

bit 5

is set when axis is accelerating

bit 6

is set when axis is decelerating

bit 7

is set when current move is complete (not used with
jog-type moves)

bit 8

is set when Module is in blend move mode