Configuration data for loop back diagnostic test, Ladder instructions for loop back diagnostics test – Rockwell Automation 1746-HSTP1 Stepper Controller Module/ User Manual User Manual

Page 61

Advertising
background image

Publication 999-121 - December 1999

5-26 Configuration and Programming

in order to generate the output pulses. Wiring for the diagnostic
feedback test is shown in the following diagram.

Configuration Data for Loop Back Diagnostic Test

N9 Configuration for Loop Back Diagnostics Test:

N9:0–3120923100 00000

Ladder Instructions for Loop Back Diagnostics Test

This rung is used to test the loopback information. Command should
equal feedback when the move is complete. The Module is shown in
slot 1 for this example.

NOTE: In the above rung, use of the EQU (equal) test means that
source A equals the command in both the MSW and LSW words;
source B in both cases, is the value reported by the loop back
diagnostic.

1

3

5

7

9

11

13

15

17

2

4

6

8

10

12

14

16

18

move
complete
1=yes

I:1

7

EQUAL
Source A I:1.2

-32753

Source B I:1.4

-32753

test okay

O:0
( )

feedback=
command MSW

EQU

EQUAL
Source A I:1.3

0

Source B I:1.5

0

feedback=
command LSW

EQU