Rockwell Automation 1746-HSTP1 Stepper Controller Module/ User Manual User Manual

Page 42

Advertising
background image

Publication 999-121 - December 1999

Configuration and Programming 5-7

word 0 bit 13, to be true and turn on the red FLT LED indicator if
attempted.

• A configuration file that does not provide the ability to home the

Module, either by means of a home limit switch and home limit
switch operations, or quadrature encoder and marker pulse
operations.

• A configuration file that does not contain a limit endpoint, either

CW or CCW

.

• A configuration file that specifies both quadrature encoder and

diagnostic feedback.

• A configuration file that specifies a marker pulse home without

specifying both a quadrature encoder and a home proximity
limit switch.

• A configuration file that specifies a home proximity limit without

specifying the home limit switch.

• A configuration file that specifies diagnostic feedback with CW

and CCW pulse outputs.

• A configuration file that calls for a starting speed outside the

design range (1-250,000 pulses per second).

Advertising