ClearCube R-Series Data Center Products User Manual

Page 115

Advertising
background image

R-Series Data Center Products User’s Guide

Hardware Upgrade and Replacement Procedures • 91

Figure 49 The Location of CPU Fan 0, CPU Fan 1, Power Headers, and the Positioning of Power Cables

Perform the following steps to replace a fan.

1. Power off the blade and remove it from the chassis. Place the blade on a stable

surface, such as a desk or a bench.

2. Position the blade so the hard disk tray is facing up (the hard disk tray is located

on the left side of the blade when you are looking at the front of the blade).

3. Use a a Phillips screwdriver to remove the four screws from the hard disk tray.

4. Use the finger holes in the center of the tray to carefully raise the tray. Do not pull

the tray straight up; rotate the tray on its long edge as shown in Figure 46 on page
86. Remo
ve SATA data cables and power cables from the hard disks.

5. Remove each fan’s power cable from the fan headers located on the motherboard.

Carefully use your fingers or needle-nose pliers to gently pull back on the
header’s release tab, located in front of the cable.

Figure 50 The Location of Power Headers

NOTE

Before disconnecting any SATA cables, mark them so you can
easily reconnect each cable to the correct hard disk. Figure 45
on page 85
shows hard disk numbering.

Fr

on

t of

Bla

d

e

CP

U

0

CPU 1

CPU 1 Fan Header

CPU 1 Fan

(Cable Exits Left Side of Fan)

CPU 0 Fan

(Cable Exits Right Side of Fan)

CPU 0 Fan Header

Fr

on

t of

Bla

d

e

CPU 0

CPU 1

Fan 0 Header

Fan 1 Header

Gently Pull Back on Fan Header

Release Tab