ClearCube R-Series Data Center Products User Manual

Page 55

Advertising
background image

R-Series Data Center Products User’s Guide

Chassis and Blade Installation • 31

Table 6 R4300 Remote Management Module Features

Connectors

Label

Color

Code

Description

CONTROL IN

Green

RJ45 connection that receives control and management signals from the previous
chassis in the Control Chain via RS-485. As many as 14 chassis can be connected per
Control Chain.

CONTROL

OUT

Green

RJ45 connection that passes control and management signals to the next chassis in
the Control Chain via RS-485.

MANAGEMENT

RJ45 connection that passes control and management signals from the chassis to the
Sentral console via Ethernet. Has two LEDs in socket to indicate Ethernet link speed
and activity. Connection is self-adapting and does not require a crossover cable.

Switches

MODE

Blue

Push button switch that toggles through the blue Mode Selected LEDs on the Connect
and Network Modules. Press this switch to display status for the connections whose
blue LED is lit.

FAN MAX

Push button switch that defeats the temperature sensor in the Fan Pack Module to set
fans to maximum speed.

RST

Pinhole switch that resets the RMM power. Switching information is not affected. RMM
configuration information is not affected.

DFLT

Pinhole switch that resets the RMM configuration information to the default
configuration settings, and then resets the RMM power. See Table 10 on page 49 for a
list of defaults. Switching information is not affected.

LEDs

RMM MODE

Bi-color LED indicates RMM Mode

Green = Primary

Yellow = Secondary

Off = Standby

RMM Reset

Control Chain

Connections

RMM Hardware

Reset Switch

Default Switch

Ethernet

Connection

RMM Status

Module

Mode Switch

Fan Mode

Switch

LEDs

RMM MODE

DHCP

DC POWER

HEALTH

RMM Status LEDs

ACTIVITY

Ethernet LEDs

LINK

Ethernet LEDs