104 • Hardware Upgrade and Replacement Procedures

R-Series Data Center Products User’s Guide

a.

Hold the green interposer so the text and labels on the top face up, and hold
the shroud so that the CLEARCUBE logo is facing up.

b. Hold the shroud above the interposer and slide the gold fingers on the left

edge of the interposer though the slot on the left edge of the shroud.

c.

Align the holes of both pieces, and make sure that the pins on the top of the
interposer rest in the recesses on the underside of the shroud.

7. Position the shroud and interposer over the gold fingers on the motherboard,

accessible on the edge of blade. Press down gently to fully seat the interposer.

8. Replace screws and screw the shroud and interposer into the blade frame.

You can now insert the blade back into a chassis, as described in “Installing PC
Blades” on page 58
, and power on the blade.

R3080D and R1350 Interposer Card

While the R3040S has two interposers, the R3080D and the R1350 blades have a
single blade interposer card. You can perform the procedure described in the previous

NOTE

Do not push or force the interposer and shroud together; the
shroud only rests on top of the interposer.

Shroud

Interposer

F

ron
t of

Bla
d

e

Interposer

Gold Fingers on Motherboard