When a blade is inserted into a chassis, it takes approximately 30 seconds for the
chassis and its RMM to detect the blade and relay its information to Sentral.

Note that the blue LCD panel and the C/Port indicator remain lit, independently of
whether the blade is powered on. These indicators run off of chassis power. After the
first on/off cycle, you can power the blade back on from the shutdown state by either
pushing the power button on the blade or the Reset/Power button on the C/Port.

Connecting Ethernet Cables

The following sections describe the configuration of R-series blade Ethernet adapters.
See “R3040S Cabling” on page 40 and “How OS Network Connections Are Mapped
to NICs on Chassis Backpack” on page 41
for more information. The following figure
shows the primary and secondary ports on the rear of an R4300 chassis.

Figure 32 The Primary and Secondary Ports in an R3400 Chassis Network Module

R3040S Blades

The type of video card installed in a blade determines the number of available
Ethernet adapters:

Traditional video card: (such as ClearCube MGA6 or off-the-shelf card)
provides four Gigabit Ethernet adapters:

Primary ports: Gigabit Ethernet

Secondary ports: Gigabit Ethernet

V52x0 PCoIP Host card: provides three Gigabit Ethernet adapters:

Odd-numbered secondary port: PCoIP communication to PCoIP zero
clients

Three other ports: Gigabit Ethernet