Turboramtest – Dell POWEREDGE M1000E User Manual

Page 1018

Advertising
background image

986

Fabric OS Command Reference

53-1001764-02

turboRamTest

2

turboRamTest

Performs a turbo SRAM test of ASIC chips.

Synopsis

turboramtest [--slot slot][-passcnt count]

ceeturboramtest [--slot slot][-passcnt count]

Description

Use this command to verify the chip SRAM located in the ASIC using the turbo-RAM BIST circuitry.
The BIST controller is able to perform the SRAM write and read operation at a much faster rate than
the PCI operation.

The turboRamTest and ceeTurboRamTest commands are platform-specific versions of the same
test. The turboRamTest command is supported on all Goldeneye/Goldeneye2 and
Condor/Condor2 platforms. Use ceeTurboRamTest on FCoE platforms only. On all other supported
platforms, use turboramtest. Refer to the Fabric OS Troubleshooting and Diagnostics Guide,
Appendix A, for a table that correlates ASIC type with switch models.

Note

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

The switch must be disabled before you can run this diagnostics.

Operands

This command has the following optional operands:

--

slot slot

Specifies the slot number on which the diagnostic operates. All eligible blade
ports in the specified slot are tested. This operand is optional. The default
value is 0 and operates on fixed port count products.

-passcnt count

Specifies the number of times to perform this test. This operand is optional.
The default value is 1.

Examples

To run the SRAM test with two passes:

switch:admin>

turboramtest -passcnt 2

Running turboramtest ..............

PASSED.

To run the SRAM test on a Brocade 8000 in default mode:

switch:admin>

turboramtest

Running turboramtest ..............

PASSED.

See Also

none

Advertising