Chassisshow – Dell POWEREDGE M1000E User Manual

Page 142

Advertising
background image

110

Fabric OS Command Reference

53-1001764-02

chassisShow

2

chassisShow

Displays all field replaceable units (FRUs).

Synopsis

chassisshow

Description

Use this command to inventory and display the FRU header content for each object in the chassis
and chassis backplane version.

Refer to the

Table 5

for more information about the lines and their meaning.

On some platforms, for certain FRU types, a few items might not be available. In these cases, the
lines are suppressed. Possibly affected lines are 1, 3 through 7, 9, and 11 through 14. In addition,
for lines 11 through 14, if there is no data set, these lines are suppressed.

Note

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability"
for details.

Operands

none

TABLE 5

Command output descriptions

Line

Description

1

If applicable, the first line displays the chassis backplane version number, in hexadecimal.

2

Object type:

CHASSIS

,

FAN

,

POWER

SUPPLY

,

SW

BLADE

(switch),

CP

BLADE

(control processor),

WWN

(world wide name), or

UNKNOWN

.

Object number:

Slot nn

(for blades),

Unit nn

(for everything else).

If the FRU is part of an assembly, a brief description, in parentheses, displays.

3

FRU header version number:

Header Version: x

4

Value to calculate the object's power consumption: positive for power supplies and negative for
consumers.

Power Consume Factor: -xxx

5

Part number (up to 14 characters):

Factory Part Num: xx-xxxxxx-xx

6

Serial number (up to 12 characters):

Factory Serial Num: xxxxxxxxxx

7

FRU manufacture date:

Manufacture:Day: dd Month: mm Year: yyyy

8

Date of the last FRU header update:

Update: Day: dd Month: mm Year: yyyy

9

Cumulative time, in days, that the FRU has been powered on:

Time Alive:dddd days

10

Current time, in days, since the FRU was last powered on:

Time Awake:ddd days

11

Externally supplied ID (up to 10 characters):

ID: xxxxxxxxxx

12

Externally supplied part number (up to 20 characters):

Part Num: xxxxxxxxxxxxxxxxxxxx

13

Externally supplied serial number (up to 20 characters):

Serial Num:xxxxxxxxxxxxxxxxxxxx

14

Externally supplied revision number (up to 4 characters):

Revision Num: xxxx

Advertising