SLIDING GLASS DOOR INSTALLATION INSTRUCTIONS


E. Perimeter Anchorage

1. From the approved shop drawings, determine the size, type, and quantity of perimeter

fasteners required. EFCO will provide fasteners for EFCO material to EFCO material only.
All perimeter fasteners are not by EFCO and should be purchased prior to arriving at the job
site. (If subframe is used, please refer to the Subframe Installation sheets.)


Due to varying opening conditions, window configurations, design pressures, and methods
of anchorage (subframe, “F” anchors, etc.), perimeter fasteners are not specified in these
instructions. For perimeter anchor type and spacing, refer to the approved shop drawings or
consult the project design professional. The design professional should analyze the
anchorage system, and take into account the following information.


a. Frame dimensions and configuration of the as installed door.
b. Material properties of the door frame.
c. Allowable tension, shear, and bending properties of the perimeter fastener.
d. Design

pressure.

e. Details of the surrounding condition for the head, sill, and jambs.
f. Relative building movements and expected thermal movement of the door system.


Substrate
Edge
Distance

Substrate
Edge
Distance

Substrate
Thickness

Shim
Height

Frame
Edge
Distance

Bearing
Surface
Edge
Distance

Bearing
Surface
Edge
Distance

Frame
Edge
Distance

Perimeter
Fastener

Note: This sketch is a typical
representation, other anchorage
systems will require similar information.