0 appendix a, 1 error messages, 1 displayed error messages – Rice Lake Intrinsically Safe User Manual

Page 52: 2 using the xe edp command, Appendix a, Displayed error messages, Using the xe edp command

Advertising
background image

46

320IS Installation Manual

7.0

Appendix A

7.1

Error Messages

The

320IS

indicator provides a number of error messages. When an error occurs, the message is shown on the

indicator LED display. Error conditions can also be checked remotely by using the XE EDP command as described

in Section 7.1.2.

7.1.1

Displayed Error Messages

The

320IS

provides a number of front panel error messages to assist in problem diagnosis. Table 7-1 lists these

messages and their meanings.

7.1.2

Using the XE EDP Command

The XE EDP command can be used to remotely query the

320IS

for the error conditions shown on the front panel.

The XE command returns two 5-digit numbers in the format:

xxxxx yyyyy

where

xxxxx

contains a decimal representation of any existing error conditions as described in Table 7-2.

If more than one error condition exists, the number returned is the sum of the values representing the error

conditions. For example, if the XE command returns the number 1040, this value represents the sum of an A/D

reference error (1024) and an A/D calibration checksum error (16).
The second number returned (

yyyyy

) uses the same bit assignments as shown in Table 7-2 to indicate whether the

test for the error condition was run. For example, the value

yyyyy

= 63487 represents the decimal equivalent of the

binary value 1111 0111 1111 1111. Using the bit assignments in Table 7-2, this value indicates all tests were run.

Error Message

Description

Solution

E A/D

A/D physical error

Call Rice Lake Weighing Systems (RLWS) Service.

EEPERR

EEPROM physical error

EVIREE

Virgin EEPROM

Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells.

EPCKSM

Parameter checksum error

EACKSM

A/D calibration checksum error

A/D converter requires recalibration. Call RLWS Service.

EFCKSM

Printer format checksum error

Call RLWS Service.

ELCKSM

Load cell calibration checksum error

Recalibrate load cells.

EIDATA

Internal RAM error

Call RLWS Service.

EREF

A/D reference error

A/D converter requires recalibration. Call RLWS Service.

LOBTRY

Low battery

ENOOPC

No optical communication

OVRFLW

Overflow

Weight value too large to be displayed.

EXDATA

External RAM error

CNTERR

Count error

DSPERR

Display error

Error

Internal program error

Check configuration. Run XE command (see Section 7.1.2 on
page 46)
to determine error type.

Call RLWS Service if unable to clear error by cycling power or if error
recurs.

^^^^^^

Overflow error

______

A/D underrange

A/D reading < –4 mV. Check scale for binding or damage.

Table 7-1. 320IS Error Messages

Advertising