3.2.5

Program Menu

Figure 3-5. Program Menu

PROGRM Menu

Parameter

Choices

Description

Level 2 submenus

PWRUPM

GO
DELAY

Power up mode. In GO mode, the indicator goes into operation immediately after a brief power
up display test.

In DELAY mode, the indicator performs a power up display test, then enters a 30–second
warm up period. If no motion is detected during the warm up period, the indicator becomes
operational when the warm up period ends; if motion is detected, the delay timer is reset and
the warm up period is repeated.

COUNT

ACCESS
SPLSIZ

Specifies whether operator has access to piece count mode and the default sample size used
for parts counting. See Level three submenu for parameter descriptions.

REGULA

NTEP
OIML
CANADA
NONE

Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.

OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero.
NONE allows tares to be acquired at any weight value.

OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no
load. NONE allows tares to be cleared at any weight value.

NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In
CANADA mode, the previous tare must be cleared before a new tare can be acquired.

NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as
long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be in
gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare.

REGWORD

GROSS
BRUTTO

Regulatory word — Sets the term displayed when weighing in gross mode. Selecting BRUTTO
replaces the Gross annunciator with Brutto.

CONSNU

000000
number

Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation.

The initial value of this parameter is set to the start up value specified on the CONSTU
parameter. Changing either CONSTU or CONSNU immediately resets the consecutive number
used for printing.

Table 3-6. Program Menu Parameters

XXXXXXX

XXXXXXX

PWRUPM

GO

OIML

REGULA

DELAY

SETPNT

PROGRM PFORMT

SERIAL

CALIBR

CONFIG FORMAT

NTEP

CANADA

COUNT

VERS

DIGIN ALGOUT

ACCESS

SPLSIZ

10

20

50

100

PCWGT

DSABLE

ENABLE

NONE

000000

number

CONSNU

000000

number

CONSTU

DATFMT

MMDDYY

DATE

DDMMYY

YYMMDD

YYDDMM

TIMFMT

12HOUR

TIME

24HOUR

TIMSEP

COLON

COMMA

number

000000

SPPWD

number

000000

STNDBY

0-255

000

ACCUM

ON

OFF

DATSEP

SLASH

DASH

SEMI

UID

5

GROSS

BRUTTO

REGWORD