320IS Plus Installation Manual

1.1

Overview

The

320IS Plus

is a single-channel digital weight indicator designed and approved to operate as an intrinsically

safe system in a wide variety of scale and weighing applications. The indicator is housed in a NEMA 4X/

IP66-rated stainless steel sealed case. The standard unit is equipped with a tilt stand base for tabletop or wall

mounting applications. The indicator front panel consists of a large (0.8 in, 20 mm, 16-segment), six-digit LED

display, 24-button keypad and eight LED annunciators. Features include:

Drives up to four 350

or eight 700 load cells

Supports four- and six-wire load cell connections (six-wire remote sense recommended)

Full-duplex fiber optic interface to attach an external I/O board located in the safe area

The

320IS Plus

is NTEP-certified and pending Measurement Canada approval for Classes I, II and III at 10,000

divisions. See Section 9.9 on page 80 for detailed specifications.
Available with optional I/O Module (PN 72721):

Four configurable digital inputs

Four digitally-controlled single pole single throw-normally open non-latching relay contact outputs

Electronic data processing (EDP) port communications at up to 38400 bps for full duplex RS-232/

RS-422/RS-485 and Current loop

Printer port communications at up to 38400 bps for full duplex RS-232/RS-422/RS-485 and Current loop

Two 16–bit analog output channels provide ±10V or ±5V, 0-5V or 0-10V, and 4-20 mA tracking of

gross or net weight values

1.2

Factory Mutual Approval

The

320IS Plus

is Factory Mutual (FM) Entity approved for:

Classes I, II, and III

Divisions 1 and 2

Groups A, B, C, D, E, F and G

T-rating T4

Only devices that have FM Entity Approval with proper entity parameters may be used unless specifically listed

in this manual or control drawing PN 72717 as part of the Rice Lake Factory Mutual systems approval. Failure to

comply with this voids the FM approval.
The classification of hazardous materials are different in the US and European standards. Because of this, the

safety class of the

320IS Plus

is declared in the following regulations:

US standards: Class I, II, III, DIV1, Groups A-G

Substitution of components may impair intrinsic safety.
To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.

1.3

Operating Modes

The

320IS Plus

has three modes of operation.

Normal (Primary) Mode

Normal mode is the default mode of the indicator. The indicator displays gross or net weights as indicated by

LED annunciators (see Figure 1-1) to indicate scale status and the type of weight value displayed.

Setup Mode

Most of the procedures described in this manual require the indicator to be in setup mode including configuration

and calibration.
To enter setup mode, remove the large fillister head screw from the enclosure backplate. Insert a non-metal

screwdriver or a similar tool into the access hole and press the setup switch once. The indicator display changes

to show the word

CONFIG

.

WARNING