8 test mode – Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual

Page 76

Advertising
background image

70

320IS Plus Installation Manual

8.8

Test Mode

In addition to normal and setup modes, test mode provides a number of diagnostic functions for the

320IS Plus

,

including:

Display raw A/D count

Calibrate A/D offset and gain

Display digital input states

Reset configuration parameters to default values

Transmit test character (“U”) from serial port

Display characters received by external serial port

Set analog output state to zero or full scale

To enter test mode, press and hold the setup switch until the front panel display shows the word

TEST

. After about

three seconds, the test mode display automatically shifts to the first test menu function, A/DTST.
Figure 8-4 shows the Test Menu structure; Figure 8-5 shows the front panel key functions in test mode. Note that,

because the Test Menu functions are all on a single menu level, the

GROSS/NET

( ) key has no function. Press

the

ZERO

( ) key to exit test mode.

Table 8-7 on page 71 summarizes the test menu functions.

Figure 8-4. Test Menu

Figure 8-5. Front Panel Key Functions in Test Mode

A/DTST

TEST

ADOFFS

ADGAIN

D/I 1

D/I 2

D/I 4

D/O 1

D/O 2

D/I 3

D/O 3

D/O 4

A/O 1

A/O 2

DEFL

T

XMTEDP

XMTPRN

ECHO

R

Exit

Not Used

Enter

Move Left

Move Right