Digital Inputs

The

I/O Module

has four digital inputs that can be used to control pre-defined operations in the indicator.

Table 9-9 outlines the various functions for the digital inputs.
Digital inputs are available on connector CN4 (see Figure 9-1 on page 73). All inputs are individually isolated

via optocouplers. Table 9-9 outlines the pin connections for CN4.

The digital inputs are designed to receive 0-24V/TTL signals on the incoming lines. Care should be taken to

apply the right DC polarity. Pins 9 and 10 (+5V and DGND) can be used to supply power to the digital inputs.

Maximum current draw should not exceed 0.25A.
See the applicable indicator installation manual for information on checking current digital input states.

9.7

Relay Contact Outputs

The

I/O Module

features four relay contact outputs, which default to open. This allows switching of maximum

+30VDC, 5A or 250VAC, 5A for each of the four digital channels.
The relay contact outputs are controlled by user-configurable setpoints. The setpoint values and operating

parameters can be defined in the SETPNT menu of the host indicator. See the indicator installation manual for

information on configuring setpoints.
Table 9-10 show pin connections for CN5 of the

I/O Module

board.

Pin

State

Description

1

Hi

Digital Input 1 (+V)

2

Low

Ground 1 (–V)

3

Hi

Digital Input 2 (+V)

4

Low

Ground 2 (–V)

5

Hi

Digital Input 3 (+V)

6

Low

Ground 3 (–V)

7

Hi

Digital Input 4 (+V)

8

Low

Ground 4 (–V)

9

Hi

+5V

10

Low

DGND

Table 9-9. CN4 Connections