5 normal mode commands, 6 batching control commands, Normal mode commands – Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual

Page 56: Batching control commands

Advertising
background image

50

320IS Plus Installation Manual

5.1.5

Normal Mode Commands

The serial transmit weight data commands (see Table 5-14) transmit data to the EDP port on demand. The SX

and EX commands are valid only in normal operating mode; all other commands are valid in either setup or

normal mode.

5.1.6

Batching Control Commands

The commands listed below provide batching control through the EDP port.

BATSTART

If the BATRUN digital input is active (low) or not assigned, The BATSTART command can be used to start the

batch program.

BATRESET

Stops the program and resets the batch program to the first batch step. Run the BATRESET command after

making changes to the batch configuration.

BATPAUSE

Stops the batch program at the current step. All digital outputs set on by the current step are set off. The BATSTA

DIGIN, BATSTART EDP command can be used to restart the batch program at the current step.

BATSTATUS

The BATSTATUS command is used to check the current status of various setpoint and batching conditions.

BATSTATUS returns 14 bytes of status data as described in Figure 5-15 on page 51. BATSTATUS is principally

used to provide status information to a controlling batch program when using the Remote I/O Interface option.
Status information returned in bytes 3 - 12 is coded as ASCII characters @ (hex 40) through 0 (hex 4F); only the

low order bits of these characters are significant. Table 5-15 on page 51 shows the low order bit assignments for

bytes 3 - 12. Use Table 5-16 on page 51 to interpret the status of the low order bits for a given ASCII character.

AO2.TWSPAN

Span calibration

0–65535

Command

Description

Response Format

SX

Start EDP streaming

OK or ??

EX

Stop EDP streaming

OK or ??

RS

Reset system

XG

Transmit gross weight in displayed units

nnnnnn UU

where nnnnnn is the weight value, UU is the units.

XN

Transmit net weight in displayed units

XT

Transmit tare weight in displayed units

XG2

Transmit gross weight in non-displayed units

XN2

Transmit net weight in non-displayed units

XT2

Transmit tare weight in non-displayed units

XE

Query system error conditions

xxxxx yyyyy

See Section 8.1.2 on page 61 for detailed information about
the XE command response format.

XA

Transmit accumulation value

UID

set unit ID

nnnnnn

CONSNUM

Set consecutive number

Table 5-14. Normal Mode EDP Commands

Command

Description

Values

Table 5-13. ALGOUT 2 EDP Commands (Continued)

Advertising