Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual

Page 54

Advertising
background image

48

320IS Plus Installation Manual

Command

Description

Values

REGULAT

Regulatory compliance

NTEP, OIML, CANADA, NONE

REGWORD

Regulatory word

GROSS, BRUTTO

CONSNUM

Consecutive number

0–999 999

CONSTUP

Consecutive number start-up value

0–999 999

PWRUPMD

Power up mode

GO, DELAY

SAMPSIZ

Sample size

5, 10, 20, 50, 100, PCWGT

CNTMOD

Count mode access

DISABLE, ENABLE

UID

Unit identifier

000000–999999

STNDBY

Standby

0-255

DATEFMT

Date format

MMDDYY, DDMMYY, YYMMDD, YYDDMM

DATESEP

Date Separator

SLASH, DASH, SEMI

TIMEFMT

Time format

12HOUR, 24HOUR

TIMESEP

Time separator

COLON, COMMA

Table 5-7. PROGRM EDP Commands

Command

Description

Values

GFMT

Gross demand print format string

See Section 6.0 on page 53 for detailed information

NFMT

Net demand print format string

SPFMT

Setpoint demand print format
string

CFMT

Count demand print format

Table 5-8. PFORMT EDP Commands

Command

Description

Values

SETPOINT

Setpoint number

1-8

KIND

Setpoint Kind

GROSSSP, NETSP,ACCUM, +RELSP, -RELSP,
%RELSP, RESREL, PAUSE, DELAY, WAITSS,
COUNTER, AUTOJOG, COZ, INMOTON,
INRANGE, -GROSS, -NET, BATCHPR, TIMER,
CONCUR

VALUE

Setpoint value

number

PSHTAR

Push tare

OFF, ON

PSHPRN

Push print

OFF, ON, WAITSS

PSHACCM

Push accumulate

OFF, ON, NQUIET

TRIP

Trip

HIGHER, LOWER, INBAND, OUTBND

BANVAL

Band value

number

HYSTER

Hysteresis

number

ALARM

Alarm

OFF,ON

PREACT

Preact

OFF, ON, LEARN, FLOW

PREVAL

Preact value

number

BATCH

Batch step enable

OFF, ON

ACCESS

Setpoint access

ON, OFF, HIDE

Table 5-9. SETPNT EDP Commands

Advertising