Serial Commands

95

10.1.2

USB Commands

Command

Function

USB.INSTALLED

Returns whether USB interface
card is installed (TRUE or
FALSE).

USB.DEVICE

Returns configured device from
the last Save and Exit. This can
be changed only in setup mode.

USB.DEVICE.LOAD

Applies the configured device
selected from the USB.DEVICE
command.

USB.DEVICE.CURRENT

Returns the current device

Table 10-2. USB Commands

10.1.3

Reporting Commands

Reporting commands send specific information to the
serial port. The commands listed in Table 10-3 can be
used in either setup mode and normal mode.

Table 10-3. Reporting Commands

Command

Function

DUMPALL

List all parameter values

SPDUMP

Print setpoint configuration

VERSION

Write 920i software version

HARDWARE

Lists option cards installed in slots 1–14.
See Section 11.1.2 on page 113 for more
information about using the HARDWARE
command.

HWSUPPORT

Reports the CPU part number (67612 = old)
(109549 = new)

XE

Returns a10-digit code representing any
error conditions currently shown on the
front panel. See Section 11.1.4 on
page 114
for more information.

10.1.4

Clear and Reset Commands

The following commands can be used to clear and reset
the 920i:

PCLR

: Program clear. Erases the loaded user program

(setup mode only).

RS

: Reset system. Resets the indicator without

resetting the configuration.

RESETCONFIGURATION

: Restores all configuration

parameters to their default values (setup mode
only). The

RESETCONFIGURATION

function can

also be initiated by pressing the

Reset Config

softkey under the VERSION menu. Use the

up

key

to select

Clear entire indicator configuration

, then press

ENTER

to reset the indicator.

Note

All load cell calibration settings are lost when
the RESETCONFIGURATION command is run.

10.1.5

Parameter Setting Commands

Parameter setting commands allow you to display or
change the current value for a particular configuration
parameter (Tables 10-4 through 10-13).

Current configuration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:

command<ENTER>

Most parameter values can be changed in setup mode
only; setpoint parameters listed in Table 10-7 on
page 100 can be changed when in no
rmal weighing
mode.

Use the following command syntax when changing
parameter values:

command=value<ENTER>

, where

value

is either a number or a parameter value. Use no spaces
before or after the equal (=) sign. If you type an
incorrect command, the display reads

??

.

For example, to set the motion band parameter on Scale
#1 to 5 divisions, type the following:

SC.MOTBAND#1=5D<ENTER>

For parameters with selectable values, enter the
command and equal sign followed by a question mark:

command=?<ENTER>

to see a list of those values. The

indicator must be in setup mode to use this function.

Note

Some parameters are valid only if other
parameters or parameter values are specified.
See the configuration menus in Section 3.2 on
page 25 for informa
tion about parameter
dependencies. Restrictions for front-panel
configuration also apply to serial command
configuration.