3 load cells, Load cells, Figure 2-2). f – Rice Lake 920i USB Installation Manual V5.05 User Manual

Page 16

Advertising
background image

10

920i Installation Manual

For cables with braided shielding, strip cable
insulation and braided shield from a point just
past the grounding clamp. Strip another half inch
(15 mm) of insulation only to expose the braid
where the cable passes through the clamp (see
Figure 2-2).

Cord Grip

Insulated
cable

Foil

(silver side out)

Grounding clamp

Shield wire

(cut)

Length of foil before folding
back on cable insulation

Cut insulation here

for foil-shielded cables

Braid

Cut insulation here

for braided cables

NOTE: Install lockwashers

first, against enclosure,

under grounding clamp

Figure 2-2. Grounding Clamp Attachment for Foil-Shielded

and Braided Cabling

For load cell cables, cut the shield wire just past
the grounding clamp. Shield wire function is
provided by contact between the cable shield and
the grounding clamp.

Route stripped cables through cord grips and
clamps. Ensure shields contact grounding clamps
as shown in Figure 2-2. Tighten grounding clamp
nuts.

Finish installation using cable ties to secure
cables inside of indicator enclosure.

2.3.3

Load Cells

To attach cable from a load cell or junction box to an
installed A/D card, route the cable through the cord
grip and ground the shield wire as described in
Section 2.3.2 on page 9.

Next, remove connector J1 from the A/D card. The
connector plugs into a header on the A/D card (see
Figure 2-3). Wire the load cell cable from the load cell
or junction box to connector J1 as shown in Table 2-1.

SIG+

SIG–

SEN+

SEN–

EXC+

EXC–

J1

JP2

JP1

Figure 2-3. Single-Channel A/D Card

If using 6-wire load cell cable (with sense wires),
remove jumpers JP1 and JP2 before reinstalling
connector J1. For 4-wire installation, leave jumpers
JP1 and JP2 on. For 6-wire load cell connections on
dual-channel A/D cards, remove jumpers JP3 and JP4
for connections to J2.

When connections are complete, reinstall load cell
connector on the A/D card and use two cable ties to
secure the load cell cable to the inside of the enclosure.

Table 2-1. A/D Card Pin Assignments

A/D Card

Connector Pin

Function

1

+SIG

2

–SIG

3

+SENSE

4

–SENSE

5

+EXC

6

–EXC

For 6-wire load cell connections to connector J1, remove
jumpers JP1 and JP2.

For 6-wire load cell connections to connector J2 (dual A/D
cards), remove jumpers JP3 and JP4.

Advertising