8 hardware and software compatibility – Rice Lake 920i USB Installation Manual V5.05 User Manual

Page 14

Advertising
background image

8

920i Installation Manual

supported by the alibi feature. The feature is
enabled using the ALIBI parameter on the
FEATURE menu; print transactions can be recalled
by assigning an

Alibi

softkey, also configured using

the FEATURE menu (see Section 3.2.3 on page 44).

• New IMAGE parameter on the FEATURE menu

allows inversion of the display image
(blue-on-white or white-on-blue) for support of the
outdoor display option. See Section 3.2.3.

• Display and printing of audit trail information is

described in Section 11.11 on page 126.

Version 3.00

• The desktop model of the 920i has been

discontinued. Drawings and parts lists for the
desktop model have been removed from this
manual.

• Added support for multi-range and multi-interval

scale configurations.

• Zero tracking, zero range, and motion band

parameters (SCALES menu) have been changed to
allow numeric values.

• Added peak hold function to SCALES menu.

• Added last zero and temporary zero functions to

calibration menus to allow recalibration based on
previous zero values.

• Enhanced print formatting with addition of audit

format and twenty auxiliary formats.

• The SERIAL menu has been restructured to provide

additional parameters for configuring RS-485
communications. See Figure 3-12 on page 40.

• A new digital input count (DINCNT) setpoint, used

to count digital input pulses, has been added to the
supported setpoint kinds. See Section 9.0 on
page 75
.

• A SENSE parameter has been added to optionally

invert the value of setpoint digital outputs. See
Section 9.0 on page 75.

• TRIGGER (digital output trigger) has been added as

a selection under the DIG I/O menu (see
Section 3.2.6 on page 52) for custom applications.

• Support has been added for EtherNet/IP and analog

input/thermocouple option cards.

1.8

Hardware and Software
Compatibility

• CPU board revision A-D was the initial release and

covered versions 1 and 2.

• Revision E was the release of version 3 which had a

minimum CPU revision, increasing memory.

• Revisions F-G used the final version of the old CPU

hardware build.

• Revision H boards are of the new design for the

replacement of PN 67612. The new CPU board is
PN 109549 and requires a minimum core of
3.14.00.

Important Information Regarding Your 920i CPU Board

Because select components of the 920i CPU have
recently become obsolete, certain design changes have
become unavoidable. Therefore, please be aware that
beginning with Revision H, the CPU board will support
only firmware 3.14 or higher. This does not affect any
pre-existing user programs, and any performance
issues should immediately be brought to the attention
of Rice Lake Weighing Systems.

Table 1-7. Hardware and Software Compatibility

CPU Board

Revision

Recommended

Boot Monitor

Minimum Core

Maximu

m Core

Minimum USB

Version

A-D

1.00

1.00.00

2.08.00

N/A

E

1.10

1.00.00

4.00.00

N/A

F-G

1.12

1.00.00

5.XX.00*

N/A

H

1.13

3.14.00

5.XX.00*

N/A

L**

2.03

5.00.00

5.XX.00*

1.01

* Refer to current release version
** USB Board