5 loading configuration files and databases, 1 loading configuration files, 2 loading database files – Rice Lake 920i USB Installation Manual V5.05 User Manual

Page 71: Loading configuration files, Loading database files

Advertising
background image

Using USB Devices

65

6.5

Loading Configuration Files and
Databases

Certain files may take extended periods of time to load
directly from a PC to the

920i

. For fastest loading times,

using a Flash drive is recommended.

It is also recommended to create a folder matching
each

920i

’s unit ID number, if using multiple

920i

units.

When loading configuration files, the unit will load the
file contained in a folder matching its UID# (the default
UID# is 1). If no folder matching the UID is found, the
unit will load the first file found.

6.5.1

Loading Configuration Files

When a file is loaded from a USB flash Drive, the
calibration is always included and will overwrite
existing calibration. To eliminate this, the 920i
configuration file should be downloaded to the
indicator before calibration is completed.

Note

Note

If loading a configuration file from a UID
subdirectory, ensure the configuration file
does not change the unit ID. Otherwise, a

.COD file in that subdirectory will not be recognized until
the UID is manually reverted to its original number.

Important

File names are limited to eight characters.

1. Using a PC, copy the desired configuration file

to the flash drive.

2. Connect the flash drive to the

920i

’s type-A

USB connector.

3. Press the

USB

softkey. If you do not have the

USB

softkey and don’t wish to add it, skip to

Step 5.

If the USB softkey is not displayed, see
Section 1.3 on page 4 and
Figure 3-13 on
page 44 if
you want to enable the softkey.

4. Select Drive and press

ENTER

.

5. Place the indicator in setup mode and navigate

to the SERIAL » PORT2 menu.

07/01/2011

01:57PM

Apply

Device

Serial Port 2 Configuration

Save

and Exit

Load File

Save File

PORT2

SERIAL

FEATURE

SCALES

PORT1

PORT3

USB: Drive

PORT4

PORT4

Figure 6-3. Port 2 screen

6. Press the

Load File

softkey.

07/01/2011

01:57PM

Apply

Device

Serial Port 2 Configuration

Save

and Exit

Load File

Save File

PORT2

SERIAL

FEATURE

SCALES

PORT1

PORT3

USB: Drive

PORT4

PORT4

Cancel

Load Configuration (*920)

Figure 6-4. Load configuration selection *

7. Select Load Configuration (*.920) and press

ENTER

.

Note

Loading a configuration file will overwrite
existing calibration values. If the file to be
loaded does not have the correct calibration,
record the current values so they can be
entered after the download.

6.5.2

Loading Database Files

Note

Note

File names are limited to eight characters. If
loading a database file, be aware the indicator
uses the alias name and a .db file extension
when saving database files.

1. Using a PC, copy the desired database file to

the flash drive.

2. Connect the flash drive to the

920i

’s type-A

USB connector.

3. Press the

USB

softkey.

If the USB softkey is not displayed, see
Section 1.3 on page 4
and Figure 3-13 on
page 44
to enable the softkey.

4. Select Drive and press

ENTER

.

07/01/2011

01:57PM

Load All Databases (*.db)

Save Configuration (*.920)

Save All Databases (*.db)

Drive

No Device

USB

Scale #

Scale

#

Figure 6-5. Load All Databases selection*

5. Select Load All Databases (*.db) and press

ENTER

.

* Available menu selections will vary depending on USB device type connected. See Table 3-6 on page 41

Advertising