62

920i Installation Manual

5.6

Connecting to the Indicator

Connect the PC serial port to port 2 of the 920i. Return
to the Hardware Configuration display, then click on
the

Connect

icon in the toolbar. iRev 4 attempts to

establish communications to the indicator.

Once communications is established, iRev 4 queries the
indicator configuration to determine whether the
indicator hardware matches the virtual hardware
configured in the current iRev 4 file. If the hardware
matches, the Hardware Configuration section of iRev 4
is disabled, preventing further changes.

If the hardware does not match, you are given the option
of either canceling the connect operation or overwriting
the iRev 4 hardware configuration with the actual
indicator hardware configuration.

5.6.1

Downloading to the Indicator

The

Download Configuration

function on the iRev 4

Communications menu allows an iRev 4 configuration
file (with or without scale calibration data), setpoint
data, widgets, database tables, or an iRite program file
to be downloaded to a connected indicator in setup
mode.

T h e

D o w n l o a d C u r r e n t D i s p l a y

f u n c t i o n o n t h e

Communications menu allows you to download only
the currently displayed object, such as the parameter
set for one scale of a multi-scale configuration.

Because less data is transferred using

Download Current

Display

, it is typically faster than a full configuration

download, but there is an increased possibility that the
download may fail due to dependencies on other
objects. If the download fails, try performing a
complete download using the

Download Configuration

function

.

A progress message is displayed during the download
indicating the progress of the download and also during
the clear memory indicating its progress.

5.6.2

Uploading Configuration to iRev

The

Upl o ad C o nfi g uration

function on the iRev 4

C o m m u n i c a t i o n s m e n u a l l o w s t h e e x i s t i n g
configuration of a connected indicator to be saved to a
file on the PC. Once saved, the configuration file
provides a backup that can be quickly restored to the
indicator if needed. Or, the file can be edited within
iRev 4, then downloaded back to the indicator.

NOTE: The indicator must be in setup mode before
uploading or downloading data.

5.7

Installing Software Upgrades

This section applies only to 920i units using a serial
board, not a USB board.

New releases of the 920i system software can be
downloaded and installed using an Internet connection
and the Rice Lake Web Update application.

NOTE:

Before upgrading to a new version of 920i system

software, ensure that a copy of the current indicator
configuration has been saved using iRev 4. Reloading the

system software requires a RESETCONFIGURATION
function and resets all configuration and calibration values
to their factory defaults.

Figure 5-5. Rice Lake Web Update Display

Click on the

Check for Updates

button in the Rice Lake

Web Update application to check if a new version of
the 920i software is available. To download a new
software version, select the new software version and
click on

Get Selection

. Once the new software is

downloaded to the PC, do the following:

1. Disconnect power to the 920i.

2. Connect the PC serial port to port 2 of the 920i.

Connection must be made at 38400 bps.

3. Open the indicator enclosure and place a

jumper across the SW1 boot mode pins (see
Figure 2-8 on page 13).

4. Power up the 920i. The indicator will stall at

the diagnostic monitor.

5. Click on the

Update Indicator

button to

d o w n l o a d t h e n e w s o f t w a r e . W h e n t h e
download begins, the following messages are
shown:

Loading…
System Diagnostic Monitor v1.14
$

?

$

?

$KNIX
$SYSLOAD

6. When the download is complete, the indicator

display shows the following messages:

$DONE

$BOOT

Loading…

7. The indicator resets and goes to weigh mode.

8. Disconnect power to the indicator. Remove the

jumper from across the SW1 boot mode pins
and place it on a single pin.

9. Power up the indicator and reload iRev 4 and

iRite files as necessary.