Rice Lake 920i USB Installation Manual V5.05 User Manual
Page 42
36
920i Installation Manual
Figure 3-7. SCALES Menu, CALIBR Submenu
See the iQUBE
2
Installation Manual, PN 106113, for information about configuring iQUBE
2
scales.
Table 3-5. SCALES Menu, CALIBR Submenu Parameters
SCALES Menu, CALIBR Submenu
Parameter
Choices
Description
Level 4, CALIBR submenu
WZERO
—
Press ENTER to display and edit the zero calibration A/D count or millivolts value.
WVAL
—
Press ENTER to display and edit the test weight value.
WSPAN
—
Press ENTER to display and edit the span calibration A/D count or millivolts value.
WLIN
POINT 1 —
POINT 5
Press ENTER to display and edit test weight and calibration values for up to five linearization points.
Perform linear calibration only after WZERO and WSPAN have been set.
REZERO
—
Press ENTER to remove an offset value from the zero and span calibrations.
Note
Use this parameter only after WZERO and WSPAN have been set. See
Section 4.2 on page 56 for more information about using this parameter.
UNITS
LB
KG
G
OZ
TN
T
GN
TROYOZ
TROYLB
LT
CUSTOM
NONE
OFF
Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; G=gram; OZ=ounce; TN=short ton; T=metric ton; GN=grain; TROYOZ=troy
ounce; TROYLB=troy pound; LT=long ton.
WZERO
WVAL
WSPAN
WLIN
REZERO
POINT 4
POINT 5
POINT 1
POINT 2
POINT 3
VISIBLE
GRADS
FORMAT
CALIBR
…
…
SCALES Menu, FORMAT Submenu, SPLIT
OFF
Parameter
Choices
Description
Table 3-4. SCALES Menu, FORMAT Submenu Parameters, SPLIT
OFF (Continued)