2 data views, 1 lc/math sensor data, Lc/math sensor data – Rice Lake MSI-8000 RF Remote Display - ScaleCore Configuration Management Program (ScCMP) User Manual

Page 11

Advertising
background image

Views

7

3.2 Data Views

The data views provide a read-only display of all sensor data. Sensors include weight, math, temperature and
voltage.

At the bottom of this display are setpoint indicators for three setpoints.

3.2.1

LC/Math Sensor Data

The LC/Math Sensor data view shows weight including ADC count, calibrated weight value with indicators
(motion, CoZ) and total/statistics data.

Figure 3-3. Data View – LC/Math

Table 3-1. LC/Math Sensor Data Parameters

Parameter

Description

Sensor ID

Sensor index. Typical range 0 to 4 for load and math sensors.

Status

Current status of the sensor. This will indicate under load, overload, under range, over range, disabled, and
other sensor status messages.

ADC Count

The ADC (Analog to Digital Converter) count as read from the sensor input.

Gross Weight

The calibrated gross weight value.

Net Weight

The calibrated net weight value.

Tare Weight

The current tare weight value.

Units

The current unit of measure.

Motion

Indicates motion on the sensor input.

CoZ

Center of Zero indication for the sensor Net Mode Indicates if the scale is currently in net or gross mode.

Total

The total accumulator value.

Stat. SumSqr

Calculated statistics value based on the total feature.

Stat. Num Ttl

Number of totals registered in the total accumulator.

Stat. Min Ttl

The minimum total value recorded in the accumulator.

Stat. Max Ttl

The maximum total value recorded in the accumulator.

Note

ADC, total and statistics may not be updated if the monitor is not enabled from the Edit menu.

Advertising