Advanced Configuration

23

6.3.1

Parameters

Parameter

Description

ID

Sensor index. Typical range 0 to 4 for load and math sensors.

Enabled

Enable or Disable the sensor. Disabling an unused sensor will improve performance of other enabled
sensors.

Type

Sensor type (Loadcell or Math).

Name

Name of this sensor. Maximum number of characters is 20.

SWFilter

The software filter level for the sensor. Typical range 0-3 where the lower number is less filtering.

Display

Capacity

The display capacity (less than or equal to the calibration capacity).

Countby

The display countby (greater than or equal to the calibration countby).

Units

The display unit of measure.

Percent Underload

The percentage of under load readings before giving an under load error.

Zero

Zero Band Hi

Zero high band in terms of percentage of capacity, range 1 to 100.

Zero Band Lo

Zero low band in terms of percentage of capacity, range 1 to 20.

AZM Range

AZM range in d.

AZM Period

AZM period in ticks (each tick is 50 milliseconds).

Power Up Zero Hi

Power up Zero high band in term of percentage of capacity, range 1 to 25.

Power Up Zero Lo

Power up Zero low band in term of percentage of capacity, range 1 to 20.

Motion

Motion Period

Motion window period in ticks (each tick is 50 milliseconds).

Motion Band

Motion detection band in d of a load cell, range 0 to 255, 0==1/2 d, 1==1d and so on.

Motion Pending Time

Motion pending time in ticks (each tick is 50 milliseconds). The time required to wait for a stable load
before zero, tare or total actions can be performed.

Tare/Total

LC Mode

Net/Gross

Tare Auto Clear

Sets the Tare Auto Clear function to Disabled, Enabled, or On Total.

Total Mode

Load cell total mode.

• Disabled
• Auto Load
• Auto Norm
• Auto Peak
• Load Drop
• On Accept
• On Command (manual)

Drop Threshold

Threshold in percentage of capacity to drop below before totaling be allowed.

Rise Threshold

Threshold in percentage of capacity to rise above before totaling be allowed.

Minimum Stable Time

Minimum stable time before it can be total.

Total On Accept Upper

Upper bound weight of on accept total mode.

Total On Accept Lower

Lower bound weight of on accept total mode.

Capacity Conversion

Selects between true and half capacity conversion. Example: 1000 lb scale true conversion is 454 kg
where half conversion is 500 kg.

Peak/Lift

Lift Threshold

Configurable upper threshold for the lift counter. Lift threshold as percentage of capacity. 0==0.5%, 1 to
100 means 1 to 100%. Above this threshold is a lift event.

Drop Threshold

Configurable lower threshold for the lift counter. Drop threshold as percentage of capacity. 0==0.5%, 1
to 100 means 1 to 100%. Below this threshold is a drop event.

Sample Speed

Sensor sampling speed for all sensor in peak hold mode.

Table 6-3. Load Cell and Math Sensor Parameters