2 controls, 3 service counters, Controls – Rice Lake MSI-8000 RF Remote Display - ScaleCore Configuration Management Program (ScCMP) User Manual

Page 24: Service counters

Advertising
background image

20 ScCMP Operator’s Manual

6.1.2

Controls

Read Device – switch to discovery mode and re-read (refresh) the entire device configuration.

Reset Device – instructs the ScaleCore device to perform an internal software reset.

Important

Configuration and calibration in the ScaleCore device will be lost.

Test Memory – performs a check of the ScaleCore device memory.

Test LC – the load cell bridge test is a troubleshooting tool that tests the connections to a load cell and attempts to
indicate which physical wire is open or shorted for a load cell connection.

Edit Device – allows editing of the User mode Code and name.

Edit Device ID – allows editing of the ScaleCore communications Device ID. It is not recommended to change
this value.

6.1.3

Service Counters

Read the service counters from the ScaleCore device. These service counters are used as a load cell fatigue
monitor.

Lift count – indicates the number of times a sensor (load cell) has exceeded a configurable load threshold. For
details on configuring this threshold value, reference Edit Lift Counter section.

Overload count – indicates the number of times a sensor (load cell) has exceeded the calibration capacity value.

Clear Service Counters

Reset all service counters back to zero.

Important

If the overload service counter is other than zero, it may indicate misuse of the load sensing device. It is
strongly recommended that all load bearing equipment be inspected if it is regularly misused.

Advertising