8 i/o, 1 parameters, Parameters – Rice Lake MSI-8000 RF Remote Display - ScaleCore Configuration Management Program (ScCMP) User Manual

Page 33

Advertising
background image

Advanced Configuration

29

6.8 I/O

The advanced view allows editing of ScaleCore listeners feature. This controls the machine to machine
communications interfaces.

Figure 6-9. Configuration View - I/O

6.8.1

Parameters

Table 6-8. Listener Parameters

Parameter

Description

Listeners

Number

Stream listener number or ID. It range from 0 to 2.

Destination ID

Destination ID, or deviceID assigned to the stream listener. 255 means broadcast ID, it is for every
device that attached the ScaleCore.

Stream Type

Stream type of this stream listener.

Sensor ID

Sensor ID. Range 0 to 16. The listener want to observe this sensor.

Output Mode

Output mode for the listener.

Interval

Time interval in 50 milliseconds per count. For example, 20 means 20x50milliSec = 1 second.

Mode/Composite

Number

Stream listener number or ID. It ranges from 0 to 2.

Print Mode

Output control mode, 0= disabled, 1=command or key press, 2= stable load, 3=continuous.

Interval

Interval period on continuous output mode. 0=as fast as it can. None zero value has unit in second.

Composite

Formatter composite string. Each digit represent a formatter number.

Formatters

Number

Formatter number range 0 to 6.

Format

Print formatter string.