Rice Lake DWM-IV Weighmeter Series 9 Setup Manual User Manual

Page 14

Advertising
background image

12

q Default settings are highlighted.

Category

Selection

Values

Description

C1

Firmware Function Settings

DPM

Display Mode

WET

Normal Weighing Mode Display

ADC

A/D Raw Counts Display

BAT

Battery Voltage Display
Secondary Remote Display Unit (Requires Optional Series 9
unit to be setup as Main Displa y Unit with C3.6 “PFM” = RDP)

RDP

Connecting the Remote Displays Communication Channel 1
(COM1) to the Main Displays COM1 allows remote key entry

Secondary Remote Operation Unit. This setting will allo w the
remote access of Di splay, Keyboard and Printer from/to a Main
Unit. Requires Optional Series 9 unit to be setup as a Main
Unit with the Remote P rinter Type on COM1 (C3.5 “TYP”=RP)
and a desired Print Format (C3.6 “PFM”=SIN, MUL or CPR)




C1.1


ROP

Also requires Bi -directional Communication be tween Main and
Remote Unit s (COM1 ••COM1) and a Printe r is attached to
this Remote Unit on COM2 with a Baud Rate setting in C3.3

HKY

Hot-key Enable (Allo ws front panel password entry to setup)

D

Disabled

C1.2

E

Enabled

ATS

Auto Power Shutd own (Off) Time (In Batt ery Operated Mode)

1~255

1 = 1 minute

C1.3

0

Auto Power Shutdown Disabled

DTM

Power On Count Down Date/Time Setti ngs Enable

D

Disabled

C1.4

E

Enabled

JPR

Journal Printer: Sub Total, Grand Total Functions Enable

D

Disabled

C1.5

E

Enabled

C2

Function Keys Enable

UNE

Allow Unit Key Toggle

D

Disable

C2.1

E

Enable

TAM

Tare Key Mode

D

Disable

P

Enable Push Button Tare Key (Default for std. Series 9 Unit)

N

Enable Numeric Tare Entry (Optional)

C2.2







NP

Enable Numeric Tare Entry and Pushbutton Tare (Optional)