Input/output connections – Rice Lake DWM-IV Weighmeter Series 9 Setup Manual User Manual
Page 20
Advertising
18
Input/Output Connections
Pin-Out Reference Table of HD1
HD1 is a 10-Pin Single Inli ne Header providing a Zero and 2-Set Point Outputs,
Each output can provid e maximum continuous sinking current of 20mA from an inter nal
+5VDC power supply (Pin No. 9/10) or 50mA with an external +5 VDC power supply.
These outputs are intended to drive Solid State Relays, driving me chanical relays may
present electrical interference problems
.
Pin No. 1
Reserved
Pin No. 2
Reserved
Pin No. 3
Reserved
Pin No. 4
Set point # 2 Output
Pin No. 5
Set point # 1 Output
Pin No. 6
Zero Output
Pin No. 7
Ground
Pin No. 8
Ground
Pin No. 9
+ 5VDC
Pin No. 10
+ 5VDC
Relay
+ 5V Source
Zero
Set point-1
Set point-2
GND
GND (If external supply is used)
Advertising