Power ON Zeroing

Upon applying power the instrument will:

i) If the applied load is less than or equal to 2% of the calibration zero

point the instrument will establish zero and clear any tare values.

ii) If the applied load is greater than 2% of the calibration zero point the

instrument will display “- - - - - - -“. The load may be removed to

allow for automatic zeroing (above) or a manual zero may be

established by pressing the ‘Zero’ button. Note: If the instrument has

been configured to not allow for zeroing greater than 2% removing

the load will be necessary.

q

Zeroing

To zero the scale press the [Zero] button.

i) 2 % Zeroing

(1) This mode will allow pushbutton zero up to 2% of full s cale

capacity. The available scale capacity will not be affected by the

zeroed amount.

ii) 100 % Zeroing

(1) This mode will allow pushbutton zero up to 100% of full sc ale

capacity. The available scale capacity will be reduced by the

zeroed amount.

q

Pushbutton Tare (If enabled)

Place the object to tare on the scale and press the [Tare] button.

The weight will be established as tare and the weight mode will

switch to net.

q

Tare by Numeric Key (Optional Series 9, if enabled)

Key in the tare value using the numeric keys then press [Tare].

In sealed applications this function is only permitted when the

gross weight is at zero.