5 program menu, Mode. see section, 20 for – Rice Lake IQ plus 590-DC Installation Manual User Manual

Page 24

Advertising
background image

20

IQ plus 590-DC Installation Manual

3.2.5

Program Menu

Figure 3-8. ProgramMenu

XXXXXXX

XXXXXXX

PWRUPM

GO

NONE

OIML

REGULA

000000

number

CONSNU

DELAY

VERS

PROGRM

PFORMT

SERIAL

CALIBR

CONFIG

FORMAT

000000

number

CONSTU

NTEP

CANADA

1

number

UID

STNDBY

COUNT

SBYDLY

LSTMOD

ACCESS

SPLSIZ

10

20

50

100

5

DSABLE

ENABLE

0

number

YES

NO

PROGRM Menu

Parameter

Choices

Description

Level 2 submenus

PWRUPM

GO
DELAY

Power up mode. In GO mode, the indicator goes into operation immediately after a brief power
up display test.

In DELAY mode, the indicator performs a power up display test, then enters a 30-second
warm up period. If no motion is detected during the warm up period, the indicator becomes
operational when the warm up period ends; if motion is detected, the delay timer is reset and
the warm up period repeated.

STNDBY

SBYDLY
LSTMOD

Specifies standby mode delay and whether indicator returns to the last operating mode or
performs a power-up sequence when standby mode ends. See Level 3 submenu parameter
descriptions.

COUNT

ACCESS
SPLSIZ

Specifies whether operator has access to piece count mode and the default sample size used
for parts counting. See Level 3 submenu parameter descriptions.

Table 3-6. Program Menu Parameters