4 indicator operations, 1 toggle gross/net/piece count mode, 2 toggle units – Rice Lake IQ plus 590-DC Installation Manual User Manual

Page 8: 3 zero scale, 4 acquire tare (pushbutton tare), 5 enter tare (keyed tare), 6 remove stored tare value, 7 print ticket, 8 acquire parts sample

Advertising
background image

4

IQ plus 590-DC Installation Manual

1.4

Indicator Operations

Basic IQ plus 590-DC operations are summarized
below:

1.4.1

Toggle Gross/Net/Piece Count Mode

Press the

GROSS/NET

key to switch the display mode

between gross, net, and piece count modes. If a tare
value has been entered or acquired, the net value is the
gross weight minus the tare. If access to piece count
mode is disabled, pressing the

GROSS/NET

key

switches between gross and net modes only.

Gross mode is shown by the

G

annunciator; net mode

is shown by the

N

annunciator. Piece count mode is

shown by the LCD annunciator adjacent to the

PC

at

the right edge of the display.

1.4.2

Toggle Units

Press the

UNITS

key to switch between primary and

secondary units. The units annunciator arrow on the
right side of the LCD display points to the units
identifier.

1.4.3

Zero Scale

1. In gross mode, remove all weight from the

scale and wait for the standstill annunciator
(

).

2. Press the

ZERO

key. The center of zero

(

) annunciator lights to indicate the

scale is zeroed.

1.4.4

Acquire Tare (Pushbutton Tare)

1. Place container on scale and wait for the

standstill annunciator (

).

2. Press the

TARE

key to acquire the tare weight

of the container.

3. Net weight is displayed and the

annunciator lit to show the tare value was
acquired.

1.4.5

Enter Tare (Keyed Tare)

1. Use the numeric keypad to enter the tare

value, then press the

TARE

key.

2. Net weight is displayed and the

annunciator lit to show the tare value was
entered.

1.4.6

Remove Stored Tare Value

1. Remove all weight from the scale and wait for

the standstill annunciator (

).

2. Press the

TARE

key. The

annunciator goes

off, indicating the tare value has been
removed.

Indicators with the REGULA parameter set to
NONE or NTEP (see Section 3.2.5 on page 20)
can clear a stored tare value using the following
procedure:

1. Press

DISPLAY TARE

to show the stored tare

value.

2. Press the

CLEAR

key twice to remove the

stored tare.

1.4.7

Print Ticket

1. Wait for the standstill annunciator (

).

2. Press the

PRINT

key to send data to the serial

port.

1.4.8

Acquire Parts Sample

1. Place empty parts container on scale. Wait for

the standstill annunciator (

), then press

TARE

to acquire the tare weight of the

container.

2. Press

MODE

to enter piece count mode.

3. Press the

SAMPLE

(

UNITS

) key to enter

sample acquisition mode.

4. The indicator display shows the message

Addnnn

, where

nnn

is the sample quantity to

be placed on the scale. You can do one of the
following:

Add the number of parts shown.

Choose a different sample size. Press the

S A M P L E

key t o s c r o l l t h r o u g h t h e

selectable sample quantities (5, 10, 20,
50, 100) or use the numeric keypad to
specify a custom sample size.

Specify a known piece weight. Press the

S A M P L E

key t o s c r o l l t h r o u g h t h e

selectable sample quantities until the

PC

WGT

prompt is shown. Use the numeric

keypad to enter the piece weight.

5. Once the sample quantity is on the scale,

press

ENTER

to calibrate the indicator for

counting the new parts. If a sample size was
specified, the indicator display shows the
message

–CNT–

as it acquires the sample

weight, then switches to count display mode
and shows the part quantity. If a known piece
weight was specified, the display switches to
count display mode immediately.

Advertising