1 manual total, 2 auto total, 3 view total – Rice Lake MSI-8000HD Remote Display User Manual

Page 16: 4 net/gross, 1 manual total 3.3.2 auto total 3.3.3 view total

Advertising
background image

12 MSI-8000HD Operator’s Manual

3.3.1

Manual Total

The

Fx-TOTAL

key under the MANUAL TOTAL mode functions in this manner:

Load is more than 1% of capacity and has not been totaled.

1. Push the

Fx-TOTAL

key to add the current load to the TOTAL weight. The

Fx

LED blinks to indicate the load value was accepted.

The TOTAL LCD annunciator and the Total weight is displayed briefly, then the
number of samples.

2. Current load has been totaled, push the

Fx-TOTAL

key to add more weight once

the 1% threshold is exceeded.

Note

If key is pressed prior to the 1% threshold being met it will display the current
total .

3.3.2

Auto Total

The

Fx-TOTAL

key under the AUTO TOTAL mode functions as Auto Total On/ Auto

Total Off.

The Auto Mode has three variations which are programmed in the SETUP menu:

AutoLoad - Any settled load above the ‘Rise above’ threshold will be

automatically totaled. Then the scale must fall below the ‘Drop below’ threshold
before another total is allowed.

AutoNorm - This mode takes the last settled load to auto total with. The total

occurs only once the Scale goes below the threshold. This allows the load to be
adjusted without a total occurring. Once load is removed, the Scale uses the last
settled reading for total.

AutoHigh - Similar to the AutoNorm mode except the Scale uses the highest

settled reading. Useful for loads that can’t be removed all at once.

3.3.3

View Total

The

Fx-VIEW TOTAL

key activates the Total weight display followed by the number

of samples. While the display is showing the Total, Total is cleared by pressing

ZERO

.

3.4 Net/Gross

Switches the display between Net and Gross modes.

Net weight is defined as Gross weight minus a Tare weight.

To switch between Net Mode and Gross Mode press the

Fx-NetGross

key (setup to

the Net/Gross function). The

Fx-NetGross

key will only function if a Tare value has

been established.

Switching back to Gross mode from Net mode will not clear the Tare value. This
allows the operator to use the Gross Mode temporarily without having to reestablish
the tare value. Only clearing or setting a new tare will change the tare value held
before switching into Gross Mode.