User Defined Function Keys 13

3.5 Peak Hold

Peak Hold automatically updates the display when a higher peak weight reading is
established.

The Peak Hold function uses a high speed mode of the A/D converter (220 samples)
allowing it to capture transient loads at a far higher rate than typical Dynamometers.

Peak hold is cleared and re-enabled with the

Fx-Peak Hold

Key. When a new peak is

detected, the Fx LED will flash three times. The accuracy of the system in Peak Hold
mode is slightly reduced to .2% of Capacity + 5d. The Filter setting is turned off while
in Peak Hold mode to ensure the fastest acquisition rate.

Example

The Peak Hold function is useful in “Dynamic” and “Fall” tests. Common tests
include “Overall Breaking Strain” (OB€), Breaking Force, and Cycled Breaking
Strain.

3.5.1

Capture Peak Force

1)

Program a function key to Peak
Hold (P-Hld)

In this example we’ll use

F1

for Peak

Hold.

2)

Prepare the test stand and test
sample.

3)

Press

ZERO

to zero out any

residual strain on the link.

4)

Press

F1 PkHold

Confirm that

the “Pk” annunciator is on.

A small jump in the reading may occur
depending on the stability of your test
device.

5)

Apply the test force. The F1 LED
will blink three times when a
new peak value ID is detected.

6)

When the force is removed,
the Peak value can be recorded.

7)

To run a new test, press

F1 PkHold

to clear the Peak

Value. Confirm the “Pk”
annunciator is off. Then repeat
steps 3-6.

Peak Hold

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

Pk

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

Pk

Example Peak Captured Value

Peak Hold

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

Peak Cleared Value

F1

F1

0

ZERO

Figure 0-1. Capture Peak Force

Advertising