3.6 2-Units/ 5-Units

The

Fx-2.Unit

key will switch the force units between pounds and kilograms.

Selecting the

Fx-5.Unit

setting will scroll through all available units: lb, kg, Tons (US

Short), Metric Tons, and kiloNewtons.

3.7 Hi-Res

Note

Only available with the MSI-7300 Dyna-Link (refer to the Dyna-Link manual
PN 152160)

Hi-Res Mode will make the MSI-8000HD more sensitive to motion and movement
resulting in a less stable display. When Hi-Res is on, the filter is automatically set to
the Hi-1 setting (if Hi-2 is already set, then the filter is not changed). This will have a
small effect on settling time. When Hi-Res is turned off, the filter setting resets to the
previous filter setting.

Pressing the

Fx-HiRes

key places the display into a temporary high resolution mode.

The high resolution mode continues until the

Fx-HiRes

key is pressed again, or power

is cycled. While in the Hi-Res mode the appropriate

Fx

LED will blink continuously

at a slow rate.

Note

Hi-Res mode does not increase the accuracy, but allows for smaller weight
incrementation to be displayed.

Use Tare or the

ZERO

key to zero out any initial error.

3.8 Print

Pressing the

F3-Print

key outputs a configured text string to the RS-232 port on the

base of the Dyna-Link.

If an F-Key is programmed as Print and the Print Setup is configured as continuous,
then the

F3-Print

key is used for Start Print/Stop Print. See Section 5.6 for more

details on data output.

Note

The Print function is always available on the

MSI-8000HD

, so it is not

necessary to program an

F1

or

F2

to “Print”. Then pushing F1 or F2 on the

scale will cause the Comm Port on the Remote to output the selected data
string.

3.9 Scan

Pressing the

Fx-Scan

key displays RF connected channels in order.