Rice Lake MSI-8000HD Remote Display User Manual

Page 42

Advertising
background image

38 MSI-8000HD Operator’s Manual

Auto Total does
not work

Load must be stable

Wait for stable symbol

to turn on

or increase filtering for more stability

Load thresholds not
reached

You must exceed 1% of capacity for
autototal to work. Then you must drop
below 0.5% of capacity for additional
weighments to register.

Charger RED light
is on

Battery deep
discharged

Disconnect charger, reconnect. If still red,
charge for 24 hours to see if it recovers.
Disconnect the charger. Open the case
and disconnect the cord from the internal
charger board to the display board.
Charge for 24 hours. If the charger LED is
still RED, the battery will need
replacement. This procedure is only
recommended for experienced
technicians.

Ambient temperature
is too high

The battery charger won’t fast charge in
high ambient temperatures. Place the
system in a cooler environment.

Ambient temperature
is too low (<-20°C,
14°F)

The battery charger won’t fast charge in
low ambient temperatures. Place the
system in a warmer environment

Charger LED
remains blue and
never turns green

The

MSI-8000HD

is

on.

Turn off the

MSI-8000HD

. While power is

being drawn fromt the battery, it won’t top
off the battery.

The battery condition
is poor.

Replace the Battery.

Problem

Possible Cause

Solution

Table 6-1. Troubleshooting