Rice Lake MSI-8000HD Remote Display User Manual

Page 41

Advertising
background image

Appendix 37

Display reading
not stable

Excessive vibration

Increase filtering or increase ‘d’ in Cal

Excessive side
loading

Improve load train symmetry

Load cell faulty

Check LC connections

Display toggles
between “Error”
and “Load”

Load exceeds
capacity

Reduce tension immediately

Faulty Load cell or
wiring

Check LC and LC wiring

Display toggles
between “Error”
and “buttn”

A key is stuck or is
being held down

Check switches for damage

Weight is on the
Scale/Dyna-Link,
RF Remote
Display does not
match

Units not mated

See setting the RF Network address
procedures

Lo Batt is blinking

Battery is low

Recharge Battery

Unit turns on,
then immediately
off

Battery is low

Recharge Battery

Load will not zero

System not stable

Wait for stable symbol

to turn on

Increase filtering for more stability

Zero out of range

Zero range might be limited. Reduce the
tension or use Tare instead

Load will not Tare
or Total

System not Stable

Wait for the stable symbol

to turn

on, or if in a mechanically noisy crane,
increase the filtering or reduce the size of
the Scale increment “d.” It is also possible
to increase the motion window. Contact
MSI if you have a problem getting the
8000 to zero, tare, or total due to stability
issues

Set point lights
blink

Set point is enabled
and the trigger point
has been reached

Disable set points if they are not needed

Manual Total does
not work

A function key is not
set to “total”

Set up Func1 or Func2 for “total”

Tension must be
stable

Increase filtering for more stability

Problem

Possible Cause

Solution

Table 6-1. Troubleshooting