3 auto-off, Yqf $2)), 6wruh – Rice Lake MSI-8000HD Remote Display User Manual

Page 22: Auto-off setup

Advertising
background image

18 MSI-8000HD Operator’s Manual

4.3 Auto-Off

The A-OFF feature, when enabled, prolongs the battery life by turning POWER off
when the scale is not in use. Any time any button is pressed, or the detected load is in
motion exceeding 10d, the time limit is reset. Therefore, the MSI-8000HD will stay
on indefinitely if the load is changing or any button is pressed at least once. With A-
OFF disabled, it will remain on; only pressing POWER will turn it off (or when the
battery is depleted).

1) With the MSI-8000 on, press the

POWER

and the

F2

keys

simultaneously.

2) The first item of the Setup Menu

is “Func1”. Scroll to “A-OFF” with
the

F2

key.

3) To setup the A-Off timing, press

F1

. The current Auto-Off time is

displayed.

4) Select the Auto Off time by

scrolling through the choices with
the

F2

key.

In this example, we’ll set 60 minutes as
the Auto-Off time.

5) When the desired time is

displayed, press

F1

. The next

item in the Setup Menu appears.

6) Either press

ZERO

to exit Setup

and store all changes, or
continue to another Setup Menu
item using the

F2

Key.

Auto-Off Setup

)YQF

$2))

Press Simultaneously

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

ENTER/SELECT

EXIT/SAVE

ZERO

0

ENTER/SELECT

2II

blinking



blinking



blinking

)YQF

Next Setup Menu Item

Store and return to

weight display

6WRUH



blinking



blinking

SCROLL

Figure 4-3. Auto-Off

Advertising