COMM Set Up 29

Serial Cable Schematic, DTE Configuration for connecting directly to a DCE printer
or other DCE devices (503489-0002 schematic).

5.10 Service Counters

All MSI’s RF Linked Scales and Dyna-Links maintain two service counters for safety.
The first counter (LFCnt) counts lifts above 25% of capacity. The second counter
(OLCnt) counts the number of times the RF Linked Scale has been overloaded. These
counters serve to warn the user to inspect the load train after a number of overloads or
a long term frequency of high capacity lifts. Service counters can only be reset by the
factory. The power up routine will be interrupted when the lift counter exceeds 16383
lifts or the overload counter exceeds 1023 overloads. Push any key to continue
operation.
Feature only available on MSI-8000HD Software release 2.00 and above. Service
counters are available on the Scale/Dyna-Link front panel Test function.