Smart Power Systems ER Series User Manual

Page 19

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 18 of 52

.208

CLEARANCE HOLE

FOR #10 SCREW

4 PL.

2.000

3.375

3.375

1.688

1.688

Hole pattern for Command & Control Center

Figure 8


6.

Flush the hoses with fresh hydraulic fluid (Dexron III). Install hoses and tighten hose
ends, using the Hose Installation Guidelines. See Figure 27 and Figure 31 for
connection locations


WARNING:


Never operate the system with the pump case drain plugged. Damage to the pump
seals will result. To do so will void the system’s warranty.

Lubricate hose fitting o-rings with clean hydraulic fluid (Dexron III) before
installation to prevent damage to them.

Hose Installation Guidelines


Never install a hose without first flushing it with clean hydraulic fluid to remove any
debris.

Never install a hose in a location where it will rub against an abrasive surface or
sharp edge or corner.

Do not position hoses with tight bend radii. Tight bends may kink and cause
serious damage to the system. Consult the hose manufacturer’s guidelines when
installing hoses.

Advertising