a. From the Normal mode display, press Mode, as if you wanted to display the oil

temperature. The screen shown in Figure 19 will be displayed instead, asking if
you want to “Run hot.” This screen will also be displayed if you attempt to start
the generator with the condition present.


b. Note the y and n labels below the Mode and On/Off switches. Press the On/Off

switch to answer “yes” and proceed to the next screen, or press Mode to answer
“no” and proceed to the oil temperature display.


Step c: Press On/Off to
answer “yes” and
override the shutdown.

Example of Command & Control Center

in hot oil fault override confirmation

Figure 20


c. If your answer was “yes” in the previous step, the confirmation screen shown in

Figure 20 will be displayed. Again note the y and n labels below the Mode and
On/Off switches. Press the On/Off switch to answer “yes” and override the
shutdown. Press Mode to answer “no” and proceed to the oil temperature
display.


Note: If you override the system and command it to operate at oil temperatures
above 175

F, the system output power may degrade and you will void the

system’s warranty.

9.

If the system detects an insufficient level of hydraulic fluid in the reservoir, it will
begin displaying an alarm. If the generator is started or was running when the fault
is detected, it will automatically be shut down in 30 minutes unless the shutdown is
overridden. To override the shutdown, perform the following steps:

Note: The oil level in the reservoir must be low for this procedure to work.