Centring with laser plummet, coarse level-up, Accurate levelling-up with electronic level, Measuring preparation 28 – Leica Geosystems TPS110C User Manual

Page 28

Advertising
background image

Measuring preparation

28

TPS100z07

TPS100z08

TPS100z09

1.

1.

3.

4.

6.

6.

6.

5.

5.

5.

5.

7.

8.

8.

8.

8.

7.

Centring with Laser Plummet, Coarse Level-Up

1. Place the instrument onto the

tripod head.
Tighten central fixing screw
of tripod slightly.

2. Turn footscrews of tribrach

into its centre position.

3. Switch on the instrument with

.

4. Switch on laser plummet with

. The electronic level

appears in the display.

5. Position tripod legs so that

the laser beam is aimed to
the ground point.

6. Firmly press in tripod legs.

7. Turn the footscrews of the

tribrach to centre the laser
beam exactly over the
ground point.

8. Move the tripod legs to

centre the circular level. The
instrument is now roughly
levelled-up.

Advertising