Menu

46

EDM Settings

Laserpointer

Off

Visible laser beam is
switched off.

On

Visible laser beam for
defining the target point is
switched on.

EDM Mode

The EDM Mode is selected
according to the desired
distance measurement accuracy
and the prism type that is being
used. Depending on selected
measuring mode the selection
prism types are different.
With TCR instruments settings
for measurements with visible
EDM mode (RL = reflectorless)
are available in addition to the
settings for measurement with
invisible EDM mode (IR =
infrared) (see following).

RL-Standard

Distance measurements
without prisms with a target
distance up to 80 m. (5 mm +
3 ppm)*

RL-Track

Continuous distance
measurement without prisms
with a target distance up to
80 m. (5 mm + 3 ppm)*

With the RL-EDM each
object in the beam is

measured (possibly branches,
cars, etc.)..

* accuracy
ppm = mm / km

EDM SETTINGS 2/3