Checking and adjusting 56 – Leica Geosystems TPS110C User Manual

Page 56

Advertising
background image

Checking and Adjusting

56

CALIBRATION DATA 2/2

Hz-Coll (c): +0°00'05"

V-Index (i): +0°00'06"

[EXIT]

Determining Instrument Errors, continued

For determining the Hz-
collimation or the V-index it is
necessary to measure in both
telescope faces. The procedure
can be started in any telescope
face.

The user is guided clearly
through the procedure. As a
result, a wrong determination of
instrument errors is eliminated.

Calibration data

Overview of the last

determined and saved values
(Hz-collimation, V-index).

Buttons

[MEAS]

Measurements are
triggered exclusively
by pressing this
button

.

is not active

during calibration

[EXIT]

Back to calibration
menu without
saving.