Cleaning the Tungsten Wire

If

reduced print quality occurs, clean the tungsten wire of the drum unit. The tungsten

wire cleaner is attached close to the lifter lower bracket.

First, turn off the power. Open the front cover and lift the clamshell release lever

to raise the clamshell. Loosen the fixing screw and remove the drum unit. Then

remove the tungsten wire cleaner from the lifter lower bracket.

Tungsten Wire Cleaner

(green)

2

.

Attach carefully the tungsten wire cleaner onto the tungsten wire through the

opening of the drum unit. Then wipe the tungsten wires by sliding the tungsten
wire cleaner from end to end several times.

Tungsten Wire Cleaner

Tungsten Wire Cleaner

3

.

Replace the tungsten wire cleaner in its original position. Re-install the drum unit

and tighten the fixing screw. Then lower the clamshell until it is locked and close

the front cover.

CAUTION

mi If the power is turned off when the MEMORY LED Is ON, document information stored

N0T€

a

in memory will be erased.

Don’t expose the drum unit to light for more than 5 minutes.