Cleaning the Tungsten Wire
If
reduced print quality occurs, clean the tungsten wire of the drum unit. The tungsten
wire cleaner is attached close to the lifter lower bracket.
First, turn off the power. Open the front cover and lift the clamshell release lever
to raise the clamshell. Loosen the fixing screw and remove the drum unit. Then
remove the tungsten wire cleaner from the lifter lower bracket.
Tungsten Wire Cleaner
(green)
2
.
Attach carefully the tungsten wire cleaner onto the tungsten wire through the
opening of the drum unit. Then wipe the tungsten wires by sliding the tungsten
wire cleaner from end to end several times.
Tungsten Wire Cleaner
Tungsten Wire Cleaner
3
.
Replace the tungsten wire cleaner in its original position. Re-install the drum unit
and tighten the fixing screw. Then lower the clamshell until it is locked and close
the front cover.
CAUTION
mi If the power is turned off when the MEMORY LED Is ON, document information stored
N0T€
a
in memory will be erased.
Don’t expose the drum unit to light for more than 5 minutes.