loW voltaGe electrical connectionS - Peak control

Steffes ETS heating equipment may be controlled by the Power Company via a

peak control signal. This signal can be sent to the equipment using a Steffes Power

Line Carrier control system, low voltage wiring, a Steffes Time Clock Module, or

line voltage control. In applications utilizing automatic charge control, outdoor

temperature information is required and can be received via an outdoor sensor or

power line carrier control system.
The Comfort Plus Hydronic system is factory configured for low voltage peak

control and is set to charge when the utility peak control switch closes. Refer to the Configuration Menu (Pages

3.14-3.15) for information on configuring the system for the application.

lOw VOlTAgE (HArd wIrEd) pEAk CONTrOl
If using the low voltage peak control option, the Com-

fort Plus Hydronic is direct wired to the power com-

pany's peak control switch. Field connections from the

peak control switch are made to the low voltage termi-

nal block through a low voltage knockout located on the

left side of the electrical panel.
Step 1 Route a low voltage circuit from the power

company’s load control or peak signaling de-

vice to the low voltage terminal block inside

the electrical compartment of the Comfort

Plus Hydronic system through one of its low

voltage wire knockouts. A black plastic bush-

ing is provided.

Step 2 Connect the field wiring to positions "RP"

and "P". (See Figure 11.)

To use the Comfort Plus to control other

loads, refer to Auxiliary load Control

(Page 3.13).

pOwEr lINE CArrIEr (plC) pEAk CONTrOl
The Steffes Power Line Carrier (PLC) control system has the ability to communicate with the Comfort Plus Hy-

dronic system through the existing electrical circuits in the structure. With the power line carrier option, hard wired

low voltage connections from the power company's peak signaling switch connect directly to the transmitting de-

vice. The switch signals peak control times to the transmitter, the transmitter sends the signals to the Comfort Plus

Hydronic system, which receives this information and responds accordingly.
In addition to providing peak control signals, the transmitter also provides outdoor temperature information for

automatic charge control, room temperature set back, and anticipated peak utility control signals (if applicable).
The PLC control is optional and must be ordered separately. If utilizing a PLC system, an Owner's and Installer's

manual will accompany the transmitting device. Refer to this manual for information on the installation and opera-

tion of the power line carrier control system.

TIME ClOCk MOdulE pEAk CONTrOl
The Steffes Time Clock Module is another option for providing a peak control signal to the Comfort Plus Hydronic.

It mounts inside the system’s low voltage electrical compartment and interfaces with the relay board via an inter-

face cable. Peak control times must be programmed into the system once the module is installed to enable the time

clock feature. Refer to the instructions provided with the Time Clock Module for more information on the installa-

tion and operation of this device.

low Voltage Terminal Block Coding

RP = Peak Control Input Common

P = Peak Control Input

AP = Anticipated Peak (Pre-Peak) Control Input

COM = Peak Control Output Common

NC = Peak Control Output (Normally Closed)

NO = Peak Control Output (Normally Open)

Low voltage wires

MUST never enter any

line voltage enclosure.

IMPORTANT

Installation

3.07

Comfort Plus Hydronic

Comfort Plus Hydronic

Installation

3.08

PEAK CONTrOl TErMINAl CONNECTIONS

FIgUrE 11

P9

Aux.

COM

NC

AP

NO

Relay

P8

O

W/

Y1

AUX

Y2 G

Outdoor

Outdoor

Y2

R

H/E

2

Y1

C

O

2

2

RP P

R

C

P1

Inputs

Peak

P7

LV Circuit Board

Comfort Plus

To Control Board

P10

Fid 2

RLY1

D4

D6

R2

R1

P11

D3

D7

D5

W E

Y1 Y2

Water

Air

P6

D1

P5

Blower

J3

J1 J2

J4

D2

To Control Board

P3

C

Blower

Speed

A

B

J5 J6

C3

D

P4

P2

Dry Contact Peak

Control Switch

Advertising
This manual is related to the following products: