Installation, Rc w y – Steffes 5140 Owner & Installers Manual User Manual

Page 18

Advertising
background image

P1

C

P9

RP

2

AP

P

Aux.

Relay

Peak

Inputs

G

TH5110D

R

C

W

Y

Honeywell

R

c

(If being used in the application)

Air Conditioner Connections

C

Y

The W/E Jumper must be removed

Hydronic Heat Thermostat, Zone

Valve End Switch, or Pump Control

P8

P2

D6

To Control Board

Fid 2

D4

Blower

To Control Board

O

D3

R2

R1

D7

D5

P11

W E

Y1 Y2

Water

J4

D1

P5

J1 J2 J3

P10

P6

D2

D

A

B

C

C3

J5 J6

Blower

Speed

P4

P3

AUX

Y2 G

Y1

O

2

2

Y2

Y1

R

Air

LV Circuit Board

Comfort Plus

P7

W/

NO

NC

COM

Outdoor

Outdoor

C

R

H/E

The Y1/Y2 Jumper must be installed

RLY1

loW voltaGe electrical connectionS - rooM

tHerMoStat

A low voltage (24VAC) room thermostat is required for room temperature control with the Comfort Plus Hydronic

system. Steffes recommends using a digital thermostat. If utilizing a mechanical thermostat, a load resistor may be

necessary due to the low current draw (.01 amps) on the heat call input circuit of the Comfort Plus system. Contact

the factory for information on thermostats available from Steffes.

The Comfort Plus Hydronic system can be used in conjunction with an air conditioner or a heat pump. Refer to the

optional Air Handler (Page 2.02) and the Low Voltage Connections for Heat Pump Application Diagram (Figures

14-15), for more information on interfacing these systems with the Comfort Plus Hydronic. If multiple heat pumps

are being interfaced, contact Steffes Corporation.

Installation

3.09

Comfort Plus Hydronic

Comfort Plus Hydronic

Installation

3.10

lOW VOlTAgE CONNECTIONS

HYDrONIC HEATINg SINglE ZONE SYSTEM

FIgUrE 12

STAND AlONE FUrNACE APPlICATION CONNECTIONS SHOWN FOr SINglE STAgE HEATINg

/ SINglE STAgE COOlINg (UNCONTrOllED AIr CONDITIONINg)

FIgUrE 13

* If multiple inputs are active, system will display

highest Heat Call values. "COOL" overrides all

inputs and stops all heating operations.

** Thermostat must be programmed to energize

reversing valve for cooling. If outdoor unit used re-

quires the reversing valve be energized for heating,

see Configuration Menu on pages 3.14-3.15.

IMPORTANT

Inputs

Peak

P7

LV Circuit Board

Comfort Plus

To Control Board

P10

Fid 2

RLY1

D4

D6

R2

R1

P11

D3

D7

D5

W E

Y1 Y2

Water

Air

P6

D1

P5

Blower

J3

J1 J2

J4

D2

To Control Board

P3

C

Blower

Speed

A

B

J5 J6

C3

D

P4

P2

P1

O

W/

Y1

AUX

Y2 G

Outdoor

Outdoor

Y2

R

H/E

2

Y1

C

O

2

2

RP P

R

C

P8

P9

Aux.

COM

NC

AP

NO

Relay

Hydronic Heat Thermostat, Zone

Valve End Switch, or Pump Control

A

B

C

D

W / E

Y1 / Y2

J1 J2 J3 J4

J5 J6

Blower

Speed

Single Stage Heat / Single Stage Cool **

Thermostat

Stage

Thermostat

Output

Heat Call Status

on Digital Display*

Discharge Air

Temperature Target

Hydronic

Varies

HC3

N/A

1

W

HC

2

L049

Fan Only

G

HCF

N/A

Cool

Y/G

COOL

N/A

Contractor Use Only