Warning, Safety precautions, Safety devices – Steffes 5140 Owner & Installers Manual User Manual

Page 3

Advertising
background image

Safety PrecautionS

1. Install all ceramic heat storage brick before ener-

gizing the system. Failure to do so may result in

equipment damage.

2. Install the pressure relief valve provided before

operating this heating system.

3. Keep combustible materials away from this

system. Storing explosive or flammable materials

near this heating system can result in an explo-

sion or fire.

4. Follow all placement and clearance requirements

as specified in this manual. (Page 3.02)

5. Make sure nothing is placed or stored on top of

this system.

6. Disconnect power to all circuits before servicing

as this heating system may be connected to more

than one branch circuit.

7. Use caution when working around the heating

system as inlet and outlet piping can be very hot.

8. Installation of and/or service to this system should be performed by a qualified technician in compliance with

information contained herein and with national, state, and local codes and requirements.

9. A repeated message display of “CORE FAIL” indicates a need for service by a qualified technician.

Safety DeviceS

The Comfort Plus Hydronic incorporates safety devices to ensure normal operating temperatures are maintained.

The chart below describes these safety devices:

Comfort Plus Hydronic

Safety Information

DEVICE NAME

FUNCTION

lOCATION

ON SYSTEM

Core Charging High

Limit Switches

(Auto Reset)

These limit switches monitor brick core charging and inter-

rupt power to the heating elements if the normal operating

temperature is exceeded.

This linear limit switch monitors the temperature of the

water in the exchanger and interrupts power to the core

blower if a water temperature of 250

o

F is exceeded. If this

limit switch opens, contact a qualified service technician.

Heat Exchanger

Limit Switch

(Manual Reset)

In the limit zone on

the left side of the

brick storage cavity.

Inside base on left side.

This linear limit switch monitors the temperature of the

water in the exchanger and interrupts power to the core

blower if a water temperature of 225

o

F is exceeded.

Outlet Water

Temperature Limit

Switch (Auto Reset)

Inside base on left side.

Pressure Relief Valve

Factory provided,

field installed to outlet

port of furnace.

If the water pressure exceeds 30 psig, the pressure relief

valve opens. Once water pressure of less than 30 psig is

achieved, the valve closes.

WARNING

Risk of explosion. Can cause injury or

death. Operating the system without the

pressure relief valve installed can cause an

explosion. Connect the pressure relief valve

in a vertical, upright position with the sup-

plied fittings. DO NOT modify this assembly.

DO NOT cap, plug, or otherwise obstruct the

outlet of the pressure relief valve.
Risk of fire. Can cause injury or death.

Violation of the clearance requirements

can cause improper operation of the equip-

ment. Maintain the placement and clearance

requirements specified.

Risk of personal injury. Plumbing and other

surfaces can be hot. Use caution when

working near the system.