Optional accessories, Static heat recovery unit, Single electrical feed kit – Steffes 5140 Owner & Installers Manual User Manual

Page 8: Primary loop kit

Advertising
background image

Static Heat recovery unit

NOTE: In applications using the Steffes Air Handler, the static heat recovery unit would not be used.

During operation of the Comfort Plus Hydronic system, some heat from the brick core storage will radiate through

its outer panels. If the system is located in an area with minimal heating requirements, such as a utility room, the

static heat recovery unit can maximize the system’s efficiency by transferring this static heat to a more desirable

location.
Features:

Connects directly to the Comfort Plus Hydronic system to interface with the

internal controls of the system for automatic operation.

Specifications:

Wattage: 130 WATTS

Motor: .1 HP, 60 Hz

Voltage: 208/240 VAC

Maximum Static Pressure: .15 inches Water Column

CFM @.15 SP: 130 CFM

If the area available to install the Comfort Plus Hydronic system is less than 100 square feet, Steffes Corporation

recommends installing a low voltage cooling thermostat, connected between R and G on the low voltage terminal

block, to maintain a temperature less than 85 degrees Fahrenheit.

optional accessories

2

Optional Accessories

2.01

Comfort Plus Hydronic

SinGle electrical feeD kit

The Steffes Comfort Plus systems have built-in circuit breakers. They are factory

configured to be field connected to multiple line voltage circuits. If single feed to the

element and blowers/control circuits is desired, the single feed kit is available to allow

the system to be powered with a one, larger line voltage circuit. Contact the factory for

ordering details.

When using single feed, the neutral conductor MUST be sized in accordance

with all applicable local, state, and national codes and regulations.

PriMary looP kit

The Comfort Plus Hydronic system requires a primary water loop which serves to regulate heat transfer from the unit’s

heat exchanger. To minimize installation time and costs for field design and engineering of this loop, Steffes Corporation

offers a primary loop kit. The kit contains the components generally installed with hydronic heat systems.

Features:

Includes a 5-gallon diaphragm type expansion tank, Grundfos brand pump (circu-

lator), air separator, air vent, pressure gauge, and pump connection conduit and

fittings.

Contains the appropriate valves to bleed air from the system during filling along

with automatic purge during system operation and draining.

Incorporates isolation flanges for quick and easy servicing of the primary loop

pump (circulator).

Offers troubleshooting isolation between the heating system and secondary

zones.

7.875

10.072

10.135

3.000

3.312

Ma

nua

l Re

set

Limi

t Sw

itch

Order Item #1302110