background image

Installation

18

975-0004-01-02 Rev D

Configuring the

C-Series

Controller

Before making any wiring connections to the

C-Series

controller

, it must be configured for the desired mode of

operation. The following sections describe the how to
configure the unit for the desired application and function.

Jumper Settings

Three sets of jumpers are located on the right side of the
controller’s circuit board. These jumpers control
equalization, low voltage reconnect, battery voltage, and
operating modes. They must be installed correctly for the unit
to operate to its maximum potential.

To enable a selection, carefully slide the jumper over the top
of both pins. This is called installing the jumper.

To disable a selection, carefully slide the jumper over only
one of the pins. This is called removing the jumper.

The factory default settings are shown in

Table 2-1, “Factory

Default Settings for C-Series Controllers” on page 19

.

Figure 2-4 Jumper Positions

Important:

Use extreme caution when installing and removing

jumpers so as not to bend the pins.

Jumper

Jumper Installed

(Jumper is on both pins)

Jumper Removed

(Jumper is only on one pin)